biodieselpictures.com A Free Place To Share Pictures Of Your Biodiesel Equipment! Sponsored by Utah Biodiesel Supply
|
| View previous topic :: View next topic |
| Author |
Message |
freesoul
Joined: 19 Nov 2008 Posts: 7
|
Posted: Tue Nov 10, 2009 6:09 pm Post subject: Rohmax Viscoplex cold weather B100 test results |
|
|
Bucks County Freedom Fuel B100 Storage Stability
Samples held at 0C / 32F
| Description: |
11-3-2009 - Day 1
B100 untreated - bright and clear B100 w/ 1.0% 10-305 - bright and clear B100 w/ 1.0% 10-330 - bright and clear B100 w/ 1.0% 10-340 - bright and clear |
|
| Filesize: |
19.65 KB |
| Viewed: |
425 Time(s) |

|
| Description: |
11-5-2009 - Day 3
B100 untreated - cloudy with increased crystallization B100 w/ 1.0% 10-305 - cloudy B100 w/ 1.0% 10-330 - cloudy B100 w/ 1.0% 10-340 - cloudy |
|
| Filesize: |
11.14 KB |
| Viewed: |
425 Time(s) |

|
| Description: |
11-6-2009 - Day 4
B100 untreated - significant crystallization, sample flows but "chunky" B100 w/ 1.0% 10-305 - cloudy, flows readily B100 w/ 1.0% 10-330 - cloudy, flows readily B100 w/ 1.0% 10-340 - cloudy, flows readily |
|
| Filesize: |
12.79 KB |
| Viewed: |
425 Time(s) |

|
| Description: |
Day 4: BCFF B100 untreated
Day 4: BCFF B100 w/ 1.0% 10-305 |
|
| Filesize: |
12.97 KB |
| Viewed: |
425 Time(s) |

|
| Description: |
11-9-2009 - Day 7
B100 untreated - 95% solid B100 w/ 1.0% 10-305 - cloudy, flows readily B100 w/ 1.0% 10-330 - cloudy, flows readily B100 w/ 1.0% 10-340 - cloudy, flows readily |
|
| Filesize: |
11.48 KB |
| Viewed: |
425 Time(s) |

|
| Description: |
Day 7: BCFF B100 w/ 1.0% 10-305
Day 7: BCFF B100 untreated |
|
| Filesize: |
9.72 KB |
| Viewed: |
425 Time(s) |

|
|
|
| Back to top |
|
 |
graydonblair Site Admin

Joined: 09 Jun 2006 Posts: 298
|
|
| Back to top |
|
 |
freesoul
Joined: 19 Nov 2008 Posts: 7
|
Posted: Sun Dec 20, 2009 6:34 pm Post subject: |
|
|
Here is there CFPP testing equipment, pretty slick. They put a fuel sample in the bottom and it uses vacuum to suck it up through a 40 micron filter. Each time they decrease the temp until it takes longer than 60 seconds to draw the sample through.
| Description: |
|
| Filesize: |
357.3 KB |
| Viewed: |
290 Time(s) |

|
|
|
| Back to top |
|
 |
|
|
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum You can attach files in this forum You can download files in this forum
|